PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
0155 00-135
Change 5
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
i.
Check fuel hoses, other hose connections
and fuel pump for leaks. Tighten
connections that leak. Replace connections
that continue to leak.
j.
Service fuel pump (WP 0709 00).
k.
Tighten fuel pump mounting screws.
l.
Check electrical leads and connectors at
heater, at control box, and at fuel pump.
Tape frayed leads. Replace damaged
connectors (WP 0382 00).
Heater fails
to cycle
for proper
shutdown.
m. Check heater control box, switches, and
light bulbs. Tighten or replace bad switches
and bulbs (WP 0702 00).
n.
Start, run and stop heater. See TM
9-2350-277-10. During start cycle, verify
that switches and lights work properly.
o.
During operation, check for unusual noises.
Check for increase in coolant temperature.