TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
0155 00-130
Change 5
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
NOTE
Additional data on Chemical Agent
Automatic Alarm Kit for the M113
FOV can be found in:
Operator’s and Unit Maintenance
Manual, TM 3-6665-225-12.
Repair Parts and Special Tools List,
TM 9-2350-277-24P.
d.
Check mounting screws on junction box.
Tighten loose screws in junction box.
TIGHTEN LOOSE SCREWS TO 72
LB-IN (8 N·M) TORQUE. Use torque
wrench (WP 0926 00, Item 79) and socket
set (WP 0926 00, Item 72).
e.
Check grommet. Replace cracked or worn
grommet.
f.
Check cable and circuit breaker terminal.
Tighten loose connections. Replace
damaged terminals.
g.
Check cables. Replace frayed or cracked
cables (WP 0919 00).