TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
88
Semi-
Annual
Capstan Drum and
Adapter (M113A3
and M1059A3)
a.
Check capstan drum and adapter. Replace
cracked or damaged drum or adapter.
Tighten loose screws or retainer.
b.
If retainer can be unscrewed from drum,
replace spring pin.
0155 00-122
Change 5


Back to Top