TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 140 of 783

TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
85
Semi-
Annual
Tents and
Stowage Brackets
(M577A3 and
M1068A3)
a.
Replace tent that has tears, breaks, fraying,
or other damage (WP 0627 00, WP 0628 00,
or see TM 10-8340-243-13&P).
b.
Tighten screws on mounting clamps and
strip.
0155 00-120
Change 5
86
Semi-
Annual
4.2 KW Generator
Set Enclosure
(M577A3 and
M1068A3)
a.
TIGHTEN OR REPLACE LOOSE OR
MISSING SCREWS ON ENCLOSURE
TO 55-60 LB-FT (75-81 N·M) TORQUE.
Use torque wrench (WP 0926 00, Item 82).
b.
Replace damaged enclosure (WP 0674 00).


Back to Top