TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 132 of 783

TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
0155 00-112
Change 5
b.
Check dome light switches, blackout bypass
switch, and fluorescent light switch for
proper operation. See TM 9-2350-277-10.
Troubleshoot faulty switches (WP 0048 00).
c.
Check that ramp door switch operates
properly. See TM 9-2350-277-10.
Troubleshoot faulty switch (WP 0040 00).
d.
Check that admittance buzzer operates
properly. See TM 9-2350-277-10.
Troubleshoot faulty buzzer. Replace
unrepairable buzzer (WP 0042 00).
e.
Check that blower operates properly. See
TM 9-2350-277-10. Troubleshoot faulty
blower (WP 0043 00).
f.
Tape frayed electrical leads.
g.
Replace damaged connectors
(WP 0382 00).


Back to Top