TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
0155 00-107
Change 5
70
Semi-
Annual
Batteries
WARNING
Battery posts and cables touched by
metal objects can short circuit and burn
you or injure you. Use caution when
you work with tools or other metal
objects. Do not wear jewelry when you
work on electrical system. Electrical
current can burn you.
NOTE
Location of batteries and connection of
battery leads varies by model. Model
M1064A3 has two ground (negative)
leads that need to be disconnected when
performing any maintenance. All other
models have one ground (negative) lead
to be disconnected.
a.
Remove battery ground lead before you
start task (WP 0338 00, WP 0340 00, or
WP 0345 00).
b.
Check battery posts and cables
(WP 0095 00).
Any leaks,
loose,
damaged,
cracked,
broken, or
missing battery
or hardware.