TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
1)
Remove driver’s power plant access
panel. See TM 9-2350-277-10.
2)
Place suitable container under primary
fuel filter. Open drain cock and drain
water and sediment from primary fuel
filter. When clean fuel starts to drain
out, close drain cock.
3)
Repeat Step a63 for secondary fuel
filter.
4)
Check for fuel leaks at primary and
secondary fuel filters while engine is
running. If leak is found, remove and
install primary and secondary fuel filter
elements and check for proper fit and
seal (WP 0202 00).
0155 00-98