TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
67
Semi-
Annual
1.0
Hydraulic System
WARNING
Hydraulic fluid is poison and can be
absorbed through your skin. Wash
off hydraulic fluid that contacts your
skin. Fire resistant hydraulic (FRH)
fluid may contain Tricresyl Phosphate
which, if taken internally, can produce
paralysis. Wear long sleeves, gloves,
goggles, and face shield. If FRH gets in
eyes, wash them immediately and get
medical aid immediately. If FRH gets
on skin, thoroughly wash with soap and
water. Wash hands thoroughly prior to
eating or smoking.
a.
Tighten or replace cracked or leaking
fittings on hydraulic reservoir or
pump (WP 0655 00, WP 0671 00, or
WP 0672 00).
Any hydraulic
leaks, fluid
not visible on
sight gauge,
cracked,
broken,
crimped,
missing,
or loose
hardware.
b.
Replace leaky pump (WP 0655 00).
c.
Tighten tubes or hoses that leak.
0155 00-99
Change 5