TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 148 of 783

TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
0155 00-128
Change 5
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
92
Semi-
Annual
Gas Particulate
Filter
NOTE
Refer to TM 3-6680-316-10 for use of
the M39 tester.
a.
Slide spring clip away from slotted
openings of precleaner (blower) assembly
and set MASTER switch and NBC POWER
switch to ON (blower must function).
b.
Remove calibrated orifice assembly from
airflow tester (6650-00-436-4212) and zero
magnetic gauge.
c.
Disconnect crew member hose (for station
being tested) from container in vehicle
and attach connector to calibrated orifice
assembly connector of airflow tester.
NOTE
An acceptable gauge reading is between
2
.6and4.3inchesofwater
.
d.
If reading is not within limits, note reading.
See TM 3-6680-316-10.
e.
Connect crew member hose to vehicle
connection. Set MASTER switch and NBC
POWER switch to OFF and recover slotted
holes in precleaner (blower) assembly with
spring clip.
NOTE
Refer repair of particulate filter to
direct maintenance personnel per TM
3-4240-276-30&P.


Back to Top