93
Semi-
Annual
Chemical Agent
Automatic Alarm
Kit (M113A3
Only)
a.
Perform preventive maintenance checks
and services every 750 miles (1,207 km),
75 hours, or semiannually, whichever
comes first.
b.
Cable maintenance is limited to replacement
of terminals (WP 0919 00).
c.
Remove distribution box from hull
(WP 0269 00). Check terminal board
and circuit breaker. Tighten loose
connection. Install distribution box on hull
(WP 0269 00).