TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 486 of 783

TM 9-2350-277-20-2
ADJUST THROTTLE VALVE (TV) MODULATOR — Continued
0213 00
NOTE
If shifts are within ranges, adjustment is complete. If not, do Step 2 and Step 3.
2.
Iftheupshift1to2isbelow7mph(11km/h)
,doADJUSTStep11again.
3.
If upshift 2 to 3 is above 18 mph (29 km/h), do ADJUST Step 12 again.
NOTE
Do Step 4 only if the minimum/maximum shift points in Step 1 have not been obtained.
4.
If more adjustment is needed, reposition throttle valve modulator lever (1) as follows:
a.
Loosen hex nuts (2), (3), and (4).
b.
Adjust lever (1) away from modulator bracket (5) if upshift 1 to 2 is below 7 mph (11 km/h).
c.
Adjust lever (1) toward modulator bracket (5) if upshift 2 to 3 is above 18 mph (29 km/h).
d.
Tighten hex nuts (2), (3), and (4).
5.
Repeat Steps 1 - 4 until shift ranges are met.
FOLLOW-THROUGH STEPS
1.
Install driver’s power plant access panel (WP 0441 00).
2.
Close power plant access door. See TM 9-2350-277-10.
END OF TASK
0213 00-6
Change 5


Back to Top