TM 9-2350-277-20-4
REPLACE POWER PLANT DOOR COMBAT LOCK — Continued
0473 00
1.
Disconnect four wiring harnesses (1) from bulkhead inside driver’s compartment.
2.
(H) Hold hand under bolt (2) from outside carrier through power plant access door opening.
3.
Drive out pin (3). Remove handle (4) and spring (5) from bolt (2). Discard drive pin.
4.
(H) Remove bolt from power plant compartment.
0473 00-2
Change 5