TM-9-2350-277-20-6

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 6 OF 6

  TM-9-2350-277-20-6 - Page 244 of 487

TM 9-2350-277-20-6
REPLACE TACHOMETER CABLE — Continued
0864 00
4.
Install new grommet (1) on cable (2). Route cable through bulkhead and install grommet in bulkhead.
NOTE
Place cable as close to carrier wall as possible to obtain maximum bend. All other cables must
be placed in front of tachometer cable.
5.
Install clamp (3) on cable (2). Secure with screw (4) and new lockwasher (5).
6.
Connect cable (2) to gauge (6).
FOLLOW-THROUGH STEPS
1.
Install hull front access cover (WP 0449 00).
2.
Install driver’s power plant access panel. See TM 9-2350-277-10.
3.
Close power plant front access door. See TM 9-2350-277-10.
END OF TASK
0864 00-7/8 blank
Change 5


Back to Top