ASSEMBLY
1.
Install contactor RC1 (2), three screws (10), washers (12), and new locknuts (11) in rear panel (13).
2.
Install lead 18A (9) in terminal T2 of contactor RC1 (2).
3.
Install lead 17A (8) in terminal T1 of contactor RC1 (2).
4.
Install lead 14A (7) in terminal 52 of contactor RC1 (2).
5.
Install lead 13D (6) in terminal 51 of contactor RC1 (2).
6.
Install leads 9A, 9B and 9C (5) in terminal L1 of contactor RC1 (2).
7.
Install leads 8G and 8E (4) in A1 of contactor RC1 (2).
8.
Install leads 8A, 8D, and 8E (3) in terminal L2 of contactor RC1 (2).
9.
Install lead 15A (1) in terminal A2 of contactor RC1 (2).
0093 00-5