TM 9-2350-277-34
NOTE
Tag leads/cables before removing/disconnecting.
4.
Remove ten screws (2), cable W5 five leads (21), and six leads (20) from terminal block TB2 (3).
5.
Remove two set screws (26), cable W6 (24), and two leads E4 (25) from terminal block TB1 (9).
6.
Remove screw (13), ground lead W632 (17), ground lead W432 (16), and two lockwashers (11) from carrier wall.
Discard lockwashers.
7.
Remove screw (13), two ground leads E5 (12), and two lockwashers (11) from carrier wall. Discard lockwashers.
8.
Remove three screws (19), locknuts (14), six washers (15), and blackout curtain (18) from inverter housing (1). Discard
locknuts.
NOTE
The new true-sine wave inverter cable has a 15-pin arrangement versus a 25-pin for older
inverters. The 25 and 15 pin cables are not interchangeable for the old and new style inverters.
9.
Disconnect two cable W15 connectors (22) from inverters IN1 and inverter IN2 (23).
009400-3
Change 5
REPLACE INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068A3
ONLY) (ALL EXCEPT OUTBACK) — Continued
0094 00