Sand the surface of the weldnut to make sure there is a bare metal to metal surface for the
ground.
9.
Install blackout curtain (18) on inverter housing (1) and secure with six washers (15), three screws (19), and new
locknuts (14).
10. Install two ground leads E5 (12) on carrier wall and secure with two new lockwashers (11) and screw (13).
11. Install ground lead W4E1 (16) and ground lead W6E1 (17) on carrier wall and secure with two new lockwashers (11)
and screw (13).
12. Connect cable W6 (24) and two leads E4 (25) on terminal block TB1 (9) and secure with two set screws (26).
13. Connect cable W5 five leads (20) and six leads (21) on terminal block TB2 (3) and secure with ten screws (2).
0094 00-11
Change 5
REPLACE INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068A3
ONLY) (ALL EXCEPT OUTBACK) — Continued
0094 00