TM 9-2350-277-34
REPLACE INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068A3
ONLY) (OUTBACK ONLY) — Continued
0094 01
17. Loosen two screws (57) on cable clamp (56) on side of inverter (31) enough to free remote cable (11) and communication
cable (55).
18. Loosen two screws (50) on cable clamp (51) securing cable (22) from inverter (31).
19. Loosen four terminal screws (58) and remove four remote cable leads (11) from inverter terminal block (59). Remove
remote cable (11).
20. Disconnect communication “comm” cable (55) from MATE/HUB connector (54) on inverter (31). Remove
communication cable (55).
21. Loosen three set screws (52) and remove three leads on cable (22) from inverter terminal block (53). Remove cable (22)
from inverter (IN1) (31).
22. Reinstall plastic cover with two screws along with two terminal covers, nuts , lockwashers, flat washers, and turbo fan
cover with four screws on inverter.
0094 01-8
Change 5