TM-9-2350-277-34

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-277-34 - Page 758 of 871

TM 9-2350-277-34
REPLACE RF 1, 2, 3, 4 CABLE ASSEMBLIES W111, W112, W113, AND W114 (M1068A3
ONLY) — Continued
0106 00
INSTALLATION
1.
Install cable assemblies in carrier. Have helper assist.
2.
Push harness into base (10) of external communications box (11). Have helper assist.
3.
Connect W111, plug P1 (1) to jack J115 (2) on signal patch panel box (3).
4.
Connect W112, plug P1 (4) to jack J116 (5) on signal patch panel box (3).
5.
Connect W113, plug P1 (6) to jack J117 (7) on signal patch panel box (3).
6.
Connect W114, plug P1 (8) to jack J118 (9) on signal patch panel box (3).
7.
Connect harness to inside of faceplate (12) of external communications box (11).
8.
Connect W111, plug P2 (13) to jack J115 (14) on faceplate (12).
9.
Connect W112, plug P2 (15) to jack J116 (16) on faceplate (12).
10. Connect W113, plug P2 (17) to jack J117 (18) on faceplate (12).
0106 00-5