Item
No.
26
Interval
Before
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER
— CONTINUED
Location
Item to Check/
Service
M117/M117A2
Panoramic
Telescope
Crewmember
Procedure
GUNNER
a.
b.
c.
Before firing, check field of view through reticle
(1) for entrapped moisture, fungus, and optical
defects. Make sure eyeshield (2) is free from
deterioration, cuts, or tears.
Check that all external surfaces of
M117/M117A2 panoramic telescope are free of
dents, cracks, rust, or corrosion.
Check all knobs (3) for damage and freedom of
movement.
Not Fully Mission
Capable If:
Loose or defec-
tive parts prevent
proper operation.
Knobs do not
turn.