TM 9--2350--311--10
2--51
Table 2--1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item
No.
Not Fully Mission
Capable If:
Crewmember
Procedure
Item to Check/
Service
Interval
30
Before
M146
Telescope Mount
(Cont)
ASSISTANT GUNNER
NOTE
Tapered pin (king pin) and cable assembly recep-
tacle should be installed on M146 telescope mount
whether or not M118A2/M118A3 elbow telescope
is installed.
b. Check cable assembly receptacle (4) of cable
assembly (5) for damage.
4
5
TAPERED PIN
(KING PIN)