Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER
Location
Item
No.
Interval
Item to Check/
Service
Crewmember
Procedure
Not Fully Mission
Capable If:
35
During
Powerplant
DRIVER
CAUTION
If you notice a shrill whine (above normal tur-
bine whine), rubbing, vibrations, and/or a sud-
den increase in exhaust smoke, shut off en-
gine and notify unit maintenance.
Check for unusual noises or vibrations.
Performance or
function is inade-
quate or there
are unusual
noises or vibra-
tions.
36
During
Recuperator
Assembly
CHIEF OF SECTION
WARNING
Do not attempt to remove drain plug complete-
ly. Hydraulic fluid in recuperator is under high
pressure.
CAUTION
If drain plug is loosened for draining fluid,
check for leaks after tightening.
To prevent damage to gasket cover of cover,
loosen cap screws to stop pins before rotating
cover.
DRAIN
PLUG
CAP
SCREW
COVER