Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER
Location
Item
No.
Interval
Item to Check/
Service
Crewmember
Procedure
Not Fully Mission
Capable If:
35
During
Powerplant
DRIVER
CAUTION
If you notice a shrill whine (above normal tur-
bine whine), rubbing, vibrations, and/or a sud-
den increase in exhaust smoke, shut off en-
gine and notify unit maintenance.
Check for unusual noises or vibrations.
Performance or
function is inade-
quate or there
are unusual
noises or vibra-
tions.
36
During
Recuperator
Assembly
CHIEF OF SECTION
WARNING
Do not attempt to remove drain plug complete-
ly. Hydraulic fluid in recuperator is under high
pressure.
CAUTION
•
If drain plug is loosened for draining fluid,
check for leaks after tightening.
•
To prevent damage to gasket cover of cover,
loosen cap screws to stop pins before rotating
cover.
DRAIN
PLUG
CAP
SCREW
COVER