Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item
No.
Not Fully Mission
Capable If:
Crewmember
Procedure
Item to Check/
Service
Interval
34.2
During
Driver’s Fixed
And Portable
Instrument
Panels
(LHR Engine
Model 7083–7391)
DRIVER
Check the following:
a. MASTER switch indicator light (1) is lit when
MASTER switch (2) is in ON position.
b. MASTER WARNING indicator light (3) is not lit
15 seconds after engine starts.
c. At temperatures above 50
°
F (10
°
C) the GLOW
PLUGS indicator light (4) flashes light for one
second when GLOW PLUGS switch (5) is
turned to ON position.
At temperatures below 50
°
F (10
°
C) the GLOW
PLUGS indicator light (4) is lit for 35 seconds
and flashes light for one minute when GLOW
PLUGS switch (5) is turned to ON position.
Operation is to
occur in tempera-
ture below 40
°
F
(5
°
C) and if
GLOW PLUGS
indicator light (4)
remains lit.
NOTE
Depending on climatic conditions, it may take
several minutes to obtain these readings.
d. ENGINE OIL PRESSURE gage (6) reads: mini-
mum of 5 psi (34 kPa) at idle (650 RPM) 30-50
psi (207-345 kPa) at 1800 RPM.
ENGINE WATER
TEMP gage (7)
or ENGINE OIL
PRESSURE
e. ENGINE WATER TEMP gage (7) reads 170
°
F
minimum, 230
°
F maximum.
gage (6) is inop-
erative or does
not read within
limits.
1
3
5
4
7
6