TM 9--2350--311--10
2--54
Change 3
Table 2--1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item
No.
Not Fully Mission
Capable If:
Crewmember
Procedure
Item to Check/
Service
Interval
33
Before
Cab Ammunition
Rack Assembly
CANNONEER NO. 1
WARNING
If cab ammunition rack assembly has projec-
tiles loaded, make sure locking caps and re-
tainer assemblies are in place. Bustle doors
must be closed and properly latched before
moving vehicle.
a. Before firing, make sure each locking cap (1)
is rotated to hold its retainer assembly (2) in
place.
b. Check to see that each end of wire ropes (3) is
securely attached to retainer and cab ammuni-
tion rack assembly (4).
1
2
3
4
34
Before
DA FORM 2408-4
CHIEF OF SECTION
Check DA Form 2408-4 to ensure that cannon has
been borescoped and recoil exercised within the
last 180 days or EFC rounds have not exceeded
2650.
Not borescoped
within last 180
days.