TM 9–2350–311–10
2–56
Change 3
Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER — CONTINUED
Location
Item
No.
Not Fully Mission
Capable If:
Crewmember
Procedure
Item to Check/
Service
Interval
36
During
Recuperator
Assembly (Cont)
CHIEF OF SECTION
a. After firing 100 rounds sustained fire, check pins
(1) in recuperator assembly (2) from outside of
vehicle and check pins (3) in recuperator head
(4) from inside of vehicle. Pins must extend from
1/4 to 3/4 inch (6.4 to 19.05 mm).
Pins (1 and 3)
cannot be
brought into
specified range.
b. If pins are not extended within this range, bleed
or fill recuperator assembly. If pins extend be-
yond 3/4 inch (19.05 mm), remove valve cap (5)
from valve (6) and add hydraulic fluid (item 20,
Appx D) until pins extend 1/4 inch (6.4 mm). If
pins extend less than 1/4 inch (3.2 mm), loosen
drain plug (7) and drain hydraulic fluid until pins
extend 1/4 inch (6.4 mm).
3
4
1
2
5
6
CAP SCREW
COVER
7
36.1
During
Variable Recoil
Assembly
CHIEF OF SECTION
CAUTION
During operation, there shall be no more than
1 ml (approximately 25 drops) of oil accumula-
tion at any seal interface location. Immediately
following this determination oil accumulations
are to be wiped clean prior to an additional five
(5) rounds.
Check for oil accumulation at seal interface(s) and
for any hydraulic leaks.