TM 9--2350--311--10
2--236
Change 4
2--15 MISFIRE PROCEDURES
2--15.1
General
a. Precautions
Conditions described in this section are rarely encountered when authorized and properly maintained ammunition is
fired in a properly maintained and operated weapon. However, to avoid injury to personnel and damage to equipment,
it is important that all concerned understand the following.
1
What is involved when this weapon fails to fire.
2
What should be done when a failure to fire occurs.
WARNING
•
Do not use charge 1 with howitzer to avoid injury to personnel.
•
When the authorized rates of fire for the howitzer are exceeded, propelling charge
cook-offs may occur within 1 minute after chambering causing injury to personnel.
CAUTION
When firing any combination of charge 8 and lower charges within the same sustained fire
mission, charge 8 rates of fire apply to prevent premature equipment failure.
3
Authorized Rates of Fire.
Maximum rate:
4 rds/min for three minutes
Sustained rate:
Charge 2--7 -- 1 rd/min
Charge 8
-- 1 rd/min for 60 minutes;
1 rd/3 min thereafter