3-7 FIRE CONTROL ALINEMENT TESTS AND MEASUREMENTS
— CONTINUED
3-7.6
M17/M117A2 Panoramic Telescope Reliability Testing — Continued
b. Testing Reliability of Special Corrections — Continued
5 Now check the following:
(a) The line of sight must be on the reference point (6).
(b) The reading on the azimuth counter (7) should not change by more than 1/4 mil.
(c) The reset counter (8) should be changed by 10 mils.
6 Repeat the steps in 4 and 5 for 20, 30, and 40 mils.
7 Repeat the steps in 4, 5, and 6 above using the right gunner’s aid counter (5) instead of the left.
8 If checks are not as stated in 5 (a), (b), and (c) above, the M117/M117A2 panoramic telescope (1) is out
of adjustment and should be reported to unit maintenance.
3-101