TM 9-2350-311-10
3-7 FIRE CONTROL ALINEMENT TESTS AND MEASUREMENTS
— CONTINUED
3-7.6
M117/M117A2 Panoramic Telescope Reliability Testing
a. Testing Reliability of Deflections
1
2
3
4
Install M117/M117A2 panoramic telescope (1) in M145/M145A1 telescope mount (2) (para 2–11.1).
Center the cross-level (3) and pitch level (4) bubbles of the M145/M145A1 telescope mount (2).
Set the gunner’s aid counter (5) to 0.
NOTE
• To prevent eye movement, a parallax shield can be made in two ways. One is to use a dust
cap with a pin hole in the center. The second way is to use a small opening marked off with
strips of tape.
• If reference point is less than 55 yards (50 m) away, you must use a parallax shield.
Sight on a reference point (6) at least 55 yards (50 m) away.
3-99