TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 1066 of 1275

TM 9-2350-311-20-1
c. Disassembly
To prevent possible chemical or biological agent casualties, contaminated gas and
particulate filters must be removed and disposed of only by adequately trained
personnel. The unit commander or senior officer in charge of maintenance personnel
assigned to remove and dispose of contaminated gas fitters must prescribe necessary
protective clothing (TM 10-277) to be worn during this operation. The officer must also
prescribe necessary safety measures, including decontamination, that must be
performed before new gas filters are installed in housing assembly (FM 3-5).
NOTE
If any part of air purifier is damaged, replace immediately.
1 Remove four airflow caps (5) from air purifier manifold (4).
2 Remove four screws (9), four Iockwashers (11 ), and air purifier manifold (4) from housing (17). Discard
Iockwashers.
12-5
WARNING