3-3 TROUBLESHOOTING CHART — CONTINUED
c. STARTER MOTOR CIRCUIT (M109A2/M109A3) —
ENGINE DOES NOT CRANK; ALL ELECTRICAL
CONTINUED
ACCESSORIES OPERATE
.
Personnel
Required
M109A2/M109A3
Two
Tools
General mechanic’s tool kit (item 64, Appx H)
Transmission left access door open (TM 9-2350-311-10)
Multimeter (item 36, Appx H)
Battery access doors open (TM 9-2350-311-10)
TA-1 probe kit (item 43, Appx H)
Portable instrument panel cover removed (para 8-17)
(Long test leads may be needed for some tests;
16 AWG wire may be used as an extension.)
A
1. Turn MASTER switch ON.
2. Check BATTERY indicator.
3. Turn MASTER switch OFF.
Is BATTERY indicator operating?
I
Troubleshoot master relay circuit
(para 3-3b).
1. Turn MASTER switch ON.
2. Check BATTERY indicator.
3. Turn MASTER switch OFF.
Is BATTERY indicator in green?
1
Troubleshoot battery power circuit
(para 3-3a).
CONTINUED ON NEXT PAGE
3-30


Back to Top