TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
c. STARTER MOTOR CIRCUIT (M109A2/M109A3) —
ENGINE DOES NOT CRANK; ALL ELECTRICAL
CONTINUED
ACCESSORIES OPERATE — CONTINUED
CONTINUED FROM STEP L
M
1. Reconnect lead 14 to output side of
STARTER switch.
2. Disconnect lead 10 from input side of
STARTER switch.
3. Place red lead of multimeter in lead 10
and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Replace STARTER switch
(para 8-17).
N
1. Reconnect lead 10 to input side of
STARTER switch.
2. Disconnect lead 10 of driver’s instrument
panel wiring harness from output side of
circuit breaker.
3. Place red lead of multimeter in output
side of circuit breaker and black lead to
ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
I
Is voltage present?
Repair or replace lead 10 of driver’s
instrument panel wiring harness
CONTINUED ON NEXT PAGE