TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
C. STARTER MOTOR CIRCUIT (M109A2/M109A3) —
ENGINE DOES NOT CRANK; ALL ELECTRICAL
CONTINUED
ACCESSORIES OPERATE — CONTINUED
CONTINUED FROM STEP E
Q
1. Reconnect connector to engine disconnect
bracket.
2. Remove powerplant from vehicle
(para 4-3).
3. Connect special equipment for operation of
equipment outside of vehicle (para 4-3).
4. Place red lead of multimeter on lead 14B at
starter solenoid and black lead to ground.
5. Place shift lever in neutral.
6. Turn MASTER switch ON, push STARTER
switch, and check for voltage.
7. Turn MASTER switch OFF.
Is voltage present?
Repair or replace lead 14B of
powerplant wiring harness (para
8-43).
1. Place red lead of multimeter on lead 82 at
starter solenoid and black lead to gerund.
2. Turn MASTER switch ON and check for
voltage.
3. Turn MASTER switch OFF.
Is voltage present?
I
Replace starter motor (para 8-14).
m
Repair or replace lead 82 of powerplant
wiring harness (para 8-43).