CONTINUED FROM STEP A
1. Reconnect air box heater fuel input hose
and install air box heater (para 5-8).
2. Turn MASTER and FLAME HEATER
switches ON.
3. Listen for a clicking sound from the fuel
solenoid or touch the fuel solenoid to confirm
that it is opening and closing.
4. Turn MASTER and FLAME HEATER
switches OFF.
Note results.
1. Disconnect air output hose at the pump and
motor assembly.
2. Turn MASTER-and FLAME HEATER
switches ON.
3. Check for airflow.
4. Turn MASTER and FLAME HEATER
switches OFF.
Note results.