TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 210 of 1275

TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
h. FLAME HEATER CIRCUIT (ENGINE MODEL
FLAME HEATER DOES NOT OPERATE — CONTINUED
7083-7396) — CONTINUED
CONTINUED FROM STEP D
1. Disconnect lead 486 from pump and motor
assembly.
2. Place red lead of multimeters in lead 486 and
black lead to ground.
3. Turn MASTER and FLAME HEATER
switches ON and check for voltage.
4. Turn MASTER and FLAME HEATER
switches OFF.
Is voltage present?
Replace pump and motor
assembly (para 5-9).
1. Reconnect lead 486 to pump and motor
assembly.
2. Disconnect powerplant wiring harness from
flame heater disconnect.
3. Place red lead of multimeters in socket A
(lead 486) and black lead to ground.
4. Turn MASTER and FLAME HEATER
switches ON and check for voltage.
5. Turn MASTER and FLAME HEATER
switches OFF.
Is voltage present?
Notify support maintenance.
CONTINUED ON NEXT PAGE
3-110


Back to Top