4-5 POWERPLANT — CONTINUED
c. Special Equipment Hookup — Continued
9
10
11
12
13
14
15
Connect two electrical connectors (86) to master relay (87).
Connect two electrical connectors (86) to voltage regulator (88).
Connect rectifier-to-voltage regulator lead 11593806 (M109A2/M109A3) or 12268303 (M109A4/M109A5)
connector (78) to rectifier (1 58).
Connect power cable (rectifier-to-alternator) (item 8, Appx H) (M109A2/M109A3) or (item 9, Appx H) (M109A4/
M109A5) (159) to rectifier (1 58).
NOTE
Step 13 applies to M109A4/M109A5 Howitzers.
Connect starter protection relay electrical lead 503 (160) to power cable (rectifier-to-alternator) (item 9, Appx
H) (159).
Connect power cable (starter circuit) (item 34, Appx H) (M109A2M109A3) or (item 10, Appx H) (M109A4/
M109A5) (161 ) to starter cable 11593782 (M109A2/M109A3) or 12353401 (M109A4/M109A5) connector
(117).
Connect power cable (starter and master warning circuit) (item 11, Appx H) (162) to master circuit wiring
harness 12268100 (M109A2/M109A3) or 12268418 (M109A4/M109A5) connector (118).
4-32