TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 813 of 1275

TM 9-2350-311 -20-1
8-85 ACCESSORY CONTROL BOX HEAT SELECTOR SWITCH-TO-CIRCUIT BREAKER LEAD
This task covers:
a. Removal
b. Disassembly
c. Assembly
d. Installation
INITIAL SETUP
Tools
General mechanic’s tool kit (item 64, Appx H))
Accessory control box
removed (para 8-20)
Accessory control box cover removed (para 8-20)
Connector
Wire
No.
Electrical Lead To:
No.
1
Circuit breaker
400A
2
Heat selector switch
400A
a. Removal
1 Remove
2 Remove
screw (1) from switch (2).
heat selector switch-to-circuit breaker lead (3) from circuit breaker (4).
8-168
Equipment Conditions


Back to Top