c. Inspection and Repair
NOTE
For definition of repair and inspection symbols, see paragraph 2-6.
1 Inspect flange (3) for cracks, distortion, and broken or missing splines. Replace if cracked, distorted, or splines
are broken or missing.
NOTE
2.0490 to 2.0500 in. (5.2045 to 5.2070 cm) pitch diameter is reading over two pins
(0.1406-in. [3.571-mm] diameters).
2 Check:
Size and fit of new parts
Wear limits
(a) Pitch diameter (A)
2.0490 to 2.0500 in. (5.2045 to 5.2070 cm)
2.0515 in. (5.2108 cm)
(b) Major diameter (B)
2.3333 to 2.3383 in. (5.9266 to 5.9393 cm)
2.3405 in. (5.9449 cm)
(c) Minor diameter (C)
2.1800 to 2.1825 in. (5.5372 to 5.5436 cm)
2.1850 in. (5.5499 cm)
3 Inspect flange plug (17) for damage or distortion. Plug must provide water- and oil-tight seal. Replace flange
assembly (3) if plug is damaged or distorted.
10-59