19–3 ACCUMULATOR ASSEMBLY, MANUAL PUMP — CONTINUED
a.
Service (Method One) — Continued
17
Install air valve cap (4) and accumulator cap (3).
18
Close nitrogen cylinder (2) shutoff valve (12) by turning clockwise.
19
Remove regulator (1) from nitrogen cylinder (2).
20
Connect elevating cylinder hydraulic lines to locking valve and tighten hex nuts if accumulator is mounted in
vehicle.
21
Refill, charge and bleed hydraulic system (para 6–3).