Open accumulator replenisher right manifold bleeder plug (1) and discharge hydraulic pressure by draining
fluid into drain pan.
Install hose on bleeder “T" (2).
Open bleeder “T" (2) at front of left variable recoil cylinder (3).
Remove two variable recoil cylinder (3) drain plugs (4) and two preformed packings (5) at rear of each vari-
able recoil cylinder. Discard preformed packings.
Drain system and catch hydraulic fluid using drain pan. Install plug on variable recoil cylinder (3).