6-16 AXIAL PUMP - CONTINUED
c. Assembly - Continued
14
Install access cover (3), four new lockwashers (9) and four machine bolts (8).
Use extreme caution when installing cover retainer because of spring-loaded components within
hand pump housing. Restrain pump shouldered shaft and cover retainer during assembly to avoid
injury.
15
Install cover retainer, pump shouldered shaft, and ball bearing group (6) in hand pump housing (7).
16
Install new key washer (4) and round nut (5).
17
Bend tab of key washer (4) to engage slot in round nut (5).
18
Secure cover (2) to access cover (3) with three washer assembled screws (1).