TM 9-2350-311-34-2
f.
Adjustment
NOTE
This alinement procedure can be done during installation of rammer assembly or with lower gun
shield and rammer assembly already installed.
1
Remove two pipe plugs (17) from access holes of lower gun shield (16).
2
Loosen two hex nuts (18) and adjust two setscrews (19) through access holes to aline rammer assembly in
cannon breech.
3
Hold setscrews (19) with a wrench and tighten two hex nuts (18).
4
Apply antiseizing compound and install two pipe plugs (17).
7-19