13-9.
COAXIAL CABLE REPAIR
General Information:
This procedure gives instructions and identifies materials recommended for repair of coaxial or other shielded cables when
standard replacement parts are not available.
Option 1:
Using matching plug and jack.
Limitations:
None
Personnel/Time Required:
1 soldier
0.4 hour
Materials/Tools:
See illustrations in this procedure for materials required.
Other Options:
Reference shielded cable repair procedures in Chapter 3.
Procedural Steps:
NOTE
Do not attempt to repair broken or damaged coaxial cables unless absolutely necessary.
Replace
the entire cable whenever possible.
1.
If replacement is not practical, install a matching plug and lack of the proper size and type for splicing the
damaged or broken part.
2.
Record BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system using
standard maintenance procedures.
13-14