TM-9-2350-358-BD

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A6

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT SUPPORT MAINTENANCE

MARCH 1994

  TM-9-2350-358-BD - Page 288 of 343

TM 9-2350-358-BD
13-14.
INTERCOM SYSTEM, INOPERATIVE - CONTINUED
Procedural Steps:
CAUTION
Do not crank or ring the field telephone because damage could occur to the AM-1780 and/or the
entire AN/VIC-1 system.
NOTE
If the AM-1780 is not operational, do steps 1,
2, and 5.
If one or more of the C-2298 control boxes
becomes inoperable, but AM-1780 is still
operational, do steps 2 through 5.
1.
Run wire in a circle throughout vehicle so that all telephones are connected to the same wire.
2.
Place TA-312 or TA-1 field telephones at station(s) where bad control boxes are located.
3.
Run field telephone wire back to AM-1780.
4.
Hook up WD-1/TT wire to "LINE" jacks of the AM-1780.
5.
Record BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system using
standard maintenance procedures.
13-20


Back to Top