TM 9-2350
-
358-BD
14-6.
MCS CIRCUIT BREAKERS DEFECTIVE
General Information:
nMCS circuit breakers provide protection for a malfunctioning electric circuit within the MCS system.
When a circuit
breaker becomes damaged it will open removing electrical power from the circuit.
The only BDAR fix is to bypass the
damaged circuit breaker.
For BDAR fix of a circuit breaker see Chapter 3, para 3-16 "Circuit Breakers Damaged".
14-7.
MCS M3 HEATER DEFECTIVE
General Information:
The M3 heater warms the air for each individual member of the crew keeping them comfortable and thereby maintaining a
high level of effectiveness and efficiency of the crew.
There is no BDAR action to return a defective heater to normal operation, however, since all heaters are identical they can
be relocated by moving from one station to another depending on critical needs and priorities.
14-8.
MCS AIR DUCT HOSES AND AIR PIPE PERFORATED
General Information:
Warmed, filtered, and conditioned air is ducted through the microclimate air pipe and air duct hoses to the crew members
at 5 separate locations in the vehicle.
Damaged air ducts allow air to escape preventing adequate air supply to all stations.
Limitations:
None
Personnel/Time Required:
•
1 soldier
•
0.1 to 0.5 hour
Materials/Tools:
•
Tape, duct (item 62, Appendix C)
•
Knife
References:
TM 9-2350-314-20-1-2
14-2