TM-9-2350-358-BD

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A6

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT SUPPORT MAINTENANCE

MARCH 1994

  TM-9-2350-358-BD - Page 285 of 343

TM 9-2350-358-BD
Limitations:
Preferred method - none
Alternate methods - possible lowered volume
Personnel/Time Required:
1 soldier
0.4 hour
Materials/Tools:
Preferred method:
Box, control, C-10456 or C-2298 VRC (scavenge from available source)
Alternate method:
Solder, lead-tin alloy (item 58, Appendix C)
Other Options:
See other methods for spicing cables in electrical Chapter 3.
Another method is fabricating a junction by removing the J-801 and J-804 connectors from a C-2298 control box.
Solder jumper wires between the corresponding connector pins.
Insulate the jumper wires and the rear of the
connectors.
A less desirable method is to remove one connector from each cable and splice the corresponding wires from the
two cables together insulate the spice.
Procedural Steps:
1.
Connect a C-2298 control box between the two CX-4723 cables.
2.
Record BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system using
standard maintenance procedures.
13-17