TM 9-2520-246-34-1
FRAME 5
1.
2.
3.
GO
Measure
Measure
Measure
NOTE
Readings must be within limits given in table 2-32.
The letter T indicates a tight fit. If readings are
not within given limits, throw away part and get
a new one.
diameter of dowel pin (1).
dowel pin bore (2).
fit of dowel pin (1) in bore (2).
TO FRAME 6
Table 2-32.
Transfer Case Dowel Pin Wear Limits
Index Number
Item/Point of Measurement
1
Dowel pin diameter
2
Dowel pin bore
1 and 2
Fit of dowel pin in bore
2-192
Size and Fit
of New Parts
(inches)
0.7501 to 0.7503
0.748 to 0.749
0.011T to 0.0023T
Wear Limits
(inches)
None
0.7498
0.0003T