TM 9-2520-246-34-1
FRAME 4
NOTE
When checking sprags, anvil and spindle ends of micro-
meter and flat back of sprag must all rest on a flat
surface as shown in view A.
Since wear on all sprags in any one sprag unit will be the
same, it is only necessary to check 5 sprags in each
assembly.
1.
Measure five sprags (1) as shown in view A.
If three or more sprags are worn
to 0.375 inch or smaller, put new sprags in sprag unit.
2.
Measure five sprags (1) as shown in view B.
If three or more sprags are worn
more than 1/16 inch on the polished edge, put new sprags in sprag unit.
END OF TASK