TM 9-2520-246-34-1
FRAME 9
NOTE
Readings must be within limits given in table 2-36.
The letter T indicates a tight fit. If readings are
not within given limits, throw away part and get
a new one.
1.
Measure fit of
2.
Measure fit of
3.
Measure fit of
GO TO FRAME 10
oil seal (1) in bore (2).
oil seal (3) in input shaft cover bore (4).
deflector (5) on flange (6).
Table 2-36.
Input Shaft Cover Fits and Tolerances
Index Number
l and 2
3 and 4
Item/Point of Measurement
Fit of oil seal in bore
Fit of oil seal in input shaft cover
bore
Fit of deflector on flange
Size and Fit
of New Parts
(inches)
0.001T to 0.007T
0.003T to 0.009T
5 and 6
0.011T to 0.024T
Wear Limit
(inches)
0.0065T
0.0020T
0.0009T
2-196