TM 9-2520-270-34
7. CHECK PISTON (1).
a. Using micrometer caliper set,
measure diameter of piston (1).
b. Replace piston (1) if measurement is
less than 1.248 inches (31.70 mm).
9. CHECK FLUID REGULATING VALVE (3).
a.
b.
9.1.
3-28
Using 1/4-inch pin punch, push pilot
valve piston (4) gently into housing (5)
and release.
If piston (4) does not return to
original position, go to step 9.1. If
piston does return to original position,
go to step 10.
REPAIR MAKEUP PUMP FLUID
REGULATING VALVE, page 3-30.
Change 2
8. CHECK SPRING (2)
a.
b.
Using inside indicator caliper, measure
free length of spring (2).
Replace spring (2) if free length is
less than 3.28-inches (83.3 mm).
10. INSTALL CONTROL VALVE PISTON (1)
AND SPRING (2).
a. Coat piston (1) with transmission oil.
b. Install piston (1) in piston bore (6).
c. Install spring (2) in piston (1).