TM 9-2520-270-34
2. REMOVE FOUR SCREWS (1) AND
LOCK WASHERS (2). DISCARD
LOCK WASHERS.
NOTE
Filter element may be found either on cap or In
hole.
4.
5.
REMOVE FLUID FILTER ELEMENT (5).
a. Pull element (5) from cap (3)
or hole (6).
b. Cover hole (6) with clean rag.
REMOVE AND DISCARD TWO
PREFORMED PACKINGS (7)
AND HYDRAULIC O-RING (8).
3. REMOVE CAP (3).
a. Using hammer and punch, rotate
cap (3) to the right. Rotate until pry
bar can be placed under a corner (4)
of cap.
b. Using pry bar under cap (3), pry
up cap and lift off.
CAUTION
Failure to clean area around access cover can
result in damage to transmission.
6. REMOVE ACCESS COVER (9)
AND GASKET (10).
a. Remove 10 screws (11) and lock
washers (12). Discard lock washers.
b. Lift off cover (9)
c. Remove and discard gasket (10).
GO TO NEXT PAGE
3-33