TM 9-2520-270-34
CAUTION
Pilot valve piston and piston bore are precision
fit parts. Do not drop, scratch, or nick piston.
Equipment can be damaged.
3. REMOVE SPRING (1) AND PILOT VALVE
PISTON (2) FROM PILOT VALVE
HOUSING (3).
6. CHECK PISTON BORE (5) IN
HOUSING (3).
a.
b.
c.
Using micrometer caliper set and
small hole gage set, measure inside
diameter of bore (5).
If measurement is 0.3135 inch
(7.96 mm) or less, go to step 7.
If measurement is more than
0.3135 inch (7.96 mm), replace valve
assembly and go to END OF TASK.
4. CLEAN FLUID REGULATING VALVE
ASSEMBLY (4).
a. Clean housing and piece parts. See
page 2-2.
5. INSPECT FLUID REGULATING VALVE
ASSEMBLY (4).
a. Inspect housing and piece parts. See
page 2-5.
7. CHECK SPRING (1).
a. Using indicator caliper, measure free
length of spring (1). Replace spring if
free length is less than 1.665 inches
(42.3 mm).
GO TO NEXT PAGE
Change 2
3-30.1